Industrial-grade Fireproof Shutters

Industrial-grade Fireproof Shutters

Safeguard Your Facility with Heavy-Duty Fire & Security Solutions

View Products +
Home - Products - Fire Rolling Shutter - Fire Rolling Shutter - Steel Fire Rated Shutter Doors with Windows

Steel Fire Rated Shutter Doors with Windows

Target Applications & Marketing

Industrial: Warehouses, factories, and logistics centers requiring compartmentalization for fire safety compliance. 

Commercial: Shopping malls, hospitals, and parking garages needing smoke control and crowd evacuation pathways. 

Residential: High-rise apartments and mixed-use buildings where space optimization and aesthetics are critical. 

THE INVISIBLE GUARDIAN: DEPLOYING SECURITY IN SECONDS.

Call to Action: Request a free fire safety audit and explore customized solutions for your project!

Why Choose Our Fire Shutters? 

1. Global Compliance: Products certified for EU, US, and Asian markets. 

2. Turnkey Solutions: From design to installation and maintenance support. 

3. Cost-Efficiency**: Reduce insurance premiums with certified fire protection. 

Steel Fire Rated Shutter Doors with Windows

Steel Fire Rated Shutter Doors with Windows

Characteristics

LIGHTWEIGHT & STRUCTURAL EFFICIENCY

LOW WEIGHT (7 KG/M²): REDUCES BUILDING LOAD SIGNIFICANTLY, IDEAL FOR LARGE SPANS (E.G., ATRIUMS, SHOPPING MALLS) WHERE STRUCTURAL LOAD CAPACITY IS LIMITED.

SUPERIOR FIRE RESISTANCE

NO WATER PROTECTION NEEDED, UNLIKE TRADITIONAL STEEL SHUTTERS, INORGANIC COMPOSITE SHUTTERS ELIMINATE THE NEED FOR WATER SPRAY SYSTEMS, SAVING WATER AND REDUCING INFRASTRUCTURE COSTS. 

SPACE-SAVING DESIGNS

FOLDABLE LIFT-TYPE VARIANTS (E.G., U-SHAPED, CURVED) FIT IRREGULAR OPENINGS WITHOUT SUPPORT COLUMNS, MAXIMIZING ARCHITECTURAL FLEXIBILITY.  

Certification Standard

EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:

EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)

EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).

EN 1363-1/2: general fire resistance test methods.

EN 13501-2: classification using test data from above 

UL 10B / UL 10C: standard fire tests for door assemblies. 

UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).

Technical data

FIRE   RATING> or =3–4   HOURS (TESTED TO GB9978/EN 1634)
TYPES, APPLICATIONS & BENEFIT
 BACKFACE TEMPERATUREAVG.   > or =380°C; MAX. SINGLE POINT > or = 180°C DUAL-TRACK DUAL-CURTAIN
CURTAIN THICKNESS10–20   MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH)LARGE   MALLS, ATRIUMS, INDUSTRIAL ZONES
OPERATION SPEED2.5–6.4   M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL)AIR-LAYER INSULATION;   NO WATER SPRAY
AIR GAP (DUAL CURTAINS) 300   MM (OPTIMIZES THERMAL INSULATION) WATER-MIST STEEL SHUTTER
SOUND INSULATIONUP   TO 42 DB REDUCTIONHIGH-HUMIDITY   AREAS (E.G., PARKING GARAGES)  
MOTOR POWER0.25–1.5   KW (AC/DC OPTIONS)RAPID COOLING; SMOKE   SUPPRESSION
MAX. DIMENSIONSWIDTH:   < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M)  FOLDABLE LIFT-TYPE
STRUCTURAL   REQUIREMENTSIRREGULAR OPENINGS   (E.G., ESCALATORS, CURVED WALLS)
WALL STRENGTHMUST   SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED.  SPACE-SAVING;   COLUMN-FREE DESIGN
OPENING TOLERANCE≤5   MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT.   INSULATED   STEEL (FIRESTAR)
APPLICATIONBUILDING   PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT!
EXTREME   CLIMATES (E.G., COLD STORAGE) 
PACKAGEINSIDE:   PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS.
MINERAL   WOOL CORE; U-VALUE < or = 0.8 W/M²K


Doors Overviews

Durability & structural integrity 

Heavy-duty materials: constructed with galvanized steel or aluminum alloy slats, reinforced with steel guides for impact resistance. 

Corrosion protection: powder-coated or anodized finishes ensure longevity in harsh environments (e.g., warehouses, parking garages). 

Wind load resistance: tested to withstand high wind pressures.

Smart & Automated Operation 

Multiple Activation Modes:

Choose from manual override, motorized control, or full automation via smoke detectors or central fire systems. 

Emergency Power Backup:

Equipped with 24V battery backups for operation during power outages. 

Remote Monitoring: Optional IoT integration for real-time status alerts and control via mobile apps. 

Space-Saving & Versatile Design 

Vertical or Horizontal Roll-Up: Adapts to tight spaces with minimal overhead clearance. 

Custom Sizes & Configurations: Available for large openings (e.g., up to 10m wide × 6m high) and curved tracks. 

Aesthetic Options: Standard colors (RAL codes) or custom prints to blend with architectural themes. 

Additional Safety Features

Smoke Sealing: Inflatable or brush seals expand under heat to block toxic smoke (meeting EN 12101-3 for smoke control). 

Safety Sensors: Infrared or photoelectric sensors prevent accidental closure on obstacles. 

Sound Insulation: Reduces noise transmission by up to 40 dB, ideal for residential-commercial mixed spaces.

RELATED SOLUTIONS

INDUSTRIAL FACILITIES

TRANSPORTATION HUBS

HEALTHCARE HOSPITAL

RESIDENTIAL BUILDINGS

GOVERNMENT INFRASTRUCTURE

COMMERCIAL COMPLEXES

CONTACT US NOW

  • RESIDENTIAL BUILDINGS
  • COMMERCIAL COMPLEXES
  • INDUSTRIAL FACILITIES
  • TRANSPORTATION HUBS
  • HEALTHCARE HOSPITAL
  • GOVERNMENT INFRASTRUCTURE

Cookies

By clicking“Allow All,” you agree to store cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.